Detailed Description
Portwest MV46 Trousers: Inherent Flame Retardant Properties, Multi-standard, and Maximum Operational Functionality
The MV46 trousers represent a cutting-edge technical solution for high-risk industrial environments. Made with inherently flame-retardant fabric that guarantees permanent protection unaltered after washing cycles, this personal protective equipment (PPE) has been rigorously certified to safeguard the user against thermal, electrical, and chemical risks, integrating a high-resistance textile architecture designed for demanding daily operations.
Technical Characteristics and Operational Capabilities
- Flame Resistance (EN ISO 11612): Their inherent flame-retardant nature provides a durable barrier against heat and flames, eliminating dependence on temporary chemical treatments.
- Electric Arc Protection (IEC 61482-2) and Welding (EN ISO 11611): Class 1 certification for welding work with protection against molten metal splashes and robust protection against the thermal effects of electric arcs (6.8 cal/cm²).
- Ergonomics and Structural Durability: Optimized design with triple-stitched seams, heavy-duty brass zippers, 9 functional pockets, and adjustable kneepad pockets that promote mobility and garment lifespan.
Safety Notice and Use Limitations
IMPORTANT: The trousers must be kept clean; the accumulation of flammable contaminants on the fabric can drastically reduce the level of flame protection. Modification or alteration is strictly prohibited, as it may invalidate CE-CAT III safety certifications and its antistatic dissipative capacity (EN 1149).
Maintenance and Care Instructions
- Washing: Wash at a maximum temperature of 60°C. CRITICAL PROHIBITION: Do not use bleach or detergents with oxidizing agents that may degrade the flame-retardant fibers.
- Drying: Tumble dry at a medium temperature. CRITICAL PROHIBITION: Do not air dry outdoors under direct and prolonged exposure to solar radiation to prevent premature fabric degradation.
- Ironing: Iron at a moderate temperature if necessary to maintain the integrity of the reflective tapes.
- Inspection: Inspect before each use for tears, punctures, or excessive wear on seams; any damage that exposes the skin or compromises the fabric requires immediate removal from service.
Portwest MV46 Trousers: Inherent Flame Retardant Properties, Multi-standard, and Maximum Operational Functionality
The MV46 trousers represent a cutting-edge technical solution for high-risk industrial environments. Made with inherently flame-retardant fabric that guarantees permanent protection unaltered after washing cycles, this personal protective equipment (PPE) has been rigorously certified to safeguard the user against thermal, electrical, and chemical risks, integrating a high-resistance textile architecture designed for demanding daily operations.
Technical Characteristics and Operational Capabilities
- Flame Resistance (EN ISO 11612): Their inherent flame-retardant nature provides a durable barrier against heat and flames, eliminating dependence on temporary chemical treatments.
- Electric Arc Protection (IEC 61482-2) and Welding (EN ISO 11611): Class 1 certification for welding work with protection against molten metal splashes and robust protection against the thermal effects of electric arcs (6.8 cal/cm²).
- Ergonomics and Structural Durability: Optimized design with triple-stitched seams, heavy-duty brass zippers, 9 functional pockets, and adjustable kneepad pockets that promote mobility and garment lifespan.
Safety Notice and Use Limitations
IMPORTANT: The trousers must be kept clean; the accumulation of flammable contaminants on the fabric can drastically reduce the level of flame protection. Modification or alteration is strictly prohibited, as it may invalidate CE-CAT III safety certifications and its antistatic dissipative capacity (EN 1149).
Maintenance and Care Instructions
- Washing: Wash at a maximum temperature of 60°C. CRITICAL PROHIBITION: Do not use bleach or detergents with oxidizing agents that may degrade the flame-retardant fibers.
- Drying: Tumble dry at a medium temperature. CRITICAL PROHIBITION: Do not air dry outdoors under direct and prolonged exposure to solar radiation to prevent premature fabric degradation.
- Ironing: Iron at a moderate temperature if necessary to maintain the integrity of the reflective tapes.
- Inspection: Inspect before each use for tears, punctures, or excessive wear on seams; any damage that exposes the skin or compromises the fabric requires immediate removal from service.
MV46 Flame-Resistant Industrial Trousers | Multi-Standard and Anti-Static Protection | Modaflame™
SKU:MV46YNRS
- Regular price
- $ 4,524.12
- Sale price
- $ 4,524.12
- Regular price
-
Normas y Certificaciones
EN 13034: EN 13034 Type PB[6]
IEC 61482-2 / 1-2: IEC 61482-2 IEC 61482-1-2 APC 1
IEC 61482-2 / 1-1: IEC 61482-2 IEC 61482-1-1 ELIM 6.4 CAL/CM²
ASTM F1959/F1959M: ASTM F1959/F1959M-12 ATPV=8.4CAL/CM2(HAF=75.8%)
ISO 11612: EN ISO 11612 A1+A2, B2,C1,F1
EN 1149-5: EN 1149-5
EN ISO 20471: EN ISO 20471 CLASS 2